Siemens PLCS, Networking, and More--DMC at the SITEC 2011 Conference

I recently had the opportunity to attend my first Siemens technical conference. The conference, called SITEC, took place May 16-20 in Atlanta, GA, and Kristie Shea and I represented DMC. SITEC is Siemens’ technical conference where solution par...


DMC to Present at the 2011 Siemens Automation Summit

DMC is excited to attend and present at the Siemens Automation Summit 2011 held from June 27-30 at Disney’s Yacht and Beach Club Resorts in Orlando, FL. The Summit is an annual conference that focuses on the end-users of Siemens automation prod...


Using Siemens S7-300 PLCs to Report System Errors

The Siemens S7-300 line of PLCs has about a million great features integrated into the programming environment. After I recently inherited a PLC project where some (many) of these were not implemented, I thought it might be a good idea to do a recap ...


VNC on Siemens WinCC Flex HMI with WinCE

A version of VNC Server is available which works on Siemens MP277 and other Siemens displays that are WinCE 5.0 or higher. The open source project can be found here: http://sourceforge.net/projects/efonvnc/ Steps 1. The MP277 uses the ARM ...


Siemens S7-1200 PLC communicates through Sinaut MD720-3 cellular modem

Many consumers, including myself, have tapped into the ever-growing functionality of mobile internet. Many people leverage this infrastructure for their mobile phone. Others are beginning to use WiMAX connections for their PCs. Not to be out-done, PL...


Redundant Control Systems: Siemens S7 400H Series PLC and WinCC

There are certain control systems, such as in nuclear power plants and airplanes, that cannot be disabled or shut down, even momentarily, because of the threat to people’s lives. In these applications, a redundant control system must be in plac...


Communication between Siemens HMIs and non-Siemens controllers

Ever wanted to use those very nice looking Siemens touchpad HMIs with a third party controller Siemens doesn't officially support? On a recent project I was presented with the following scenario: a customer already had several Siemens touch-scree...


Vijeo Designer Version Control with Tortoise SVN

I was working with Vijeo Designer 5.0 on a recent project and, overall, found it rather enjoyable to work with. Vijeo Designer is the Schneider Electric / Telemecanique programming software for the Magelis XBT-GT HMI's along with several other SC...


If you have never heard about Genesis32 SCADA package from Iconics, this is the right time to learn more about it before we continue. I shall wait right here... Good, now you know what I am talking about. We'll talk about GraphWorX32, this ...


DMC Achieves Wonderware Certified Integrator Status

I am proud to announce that DMC has achieved Certified Wonderware Integrator Status. To achieve Certified System Integrator Status, DMC has fulfilled the following certification requirements of the Wonderware SI Ecosystem Program: Two or more d...